PassFAS

Strategy with printed code books

Exam day · all levels

An open-book exam is usually failed on time, not on knowledge. With printed books the winning skill is knowing which page to open: chapter, table, section.

LevelQuestionsTimePace per questionFirst pass
I85110 min1 min 18 s≈ 60 min
II110155 min1 min 25 s≈ 85 min
III115170 min1 min 29 s≈ 95 min

Two passes

  1. First pass (about 55% of your time): answer everything you know right away. If a question needs a lookup you cannot do in about 45 seconds, pick your best answer, flag it and move on.
  2. Second pass (about 40%): return to the flagged questions from the review screen and look them up with your tabs. Level II and III questions often need two lookups (for example a code section plus a table), so budget more time here.
  3. Last 10 minutes: make sure nothing is left blank. There is no penalty for wrong answers.

Time checks: be at about 25% of the questions after 20% of the time, at 50% after 45%, and at 75% after 70%.

Know the map of NFPA 72 (2022)

The first number of every section is its chapter (17.15 is in Chapter 17). If you know which chapter covers a topic, you can open the book within a few seconds.

ChapterCoversTypical questions
3DefinitionsAlarm vs. supervisory vs. trouble signal, listed vs. approved, IDC/SLC/NAC
7DocumentationRecord of completion, record drawings, documentation cabinet
10FundamentalsPower supplies, batteries, signal annunciation, impairments
12Circuits and PathwaysClass A/B/X, survivability levels, monitoring for integrity
14Inspection, Testing, and MaintenanceTable 14.3.1, Table 14.4.3.2, sensitivity, records
17Initiating DevicesDetector location and spacing, pull stations, waterflow, supervisory
18Notification AppliancesdBA rules, mounting heights, candela tables, corridors
21Emergency Control Function InterfacesRelays within 3 ft, elevator recall and shutdown
23Protected Premises Alarm and Signaling SystemsPositive alarm sequence, alarm verification
24Emergency Communications SystemsVoice evacuation basics
26Supervising Station Alarm SystemsCentral station, DACT, retransmission
29Single- and Multiple-Station Alarms and Household SystemsSmoke alarms
Annex AExplanatory material (not mandatory)Background for sections marked with an asterisk (*)

In NFPA 70, Article 760 sits in Chapter 7 (Special Conditions); wiring methods (Article 300) are in Chapter 3; conductor properties (Chapter 9, Table 8) and conduit fill (Chapter 9, Table 1 and Annex C) are at the back of the book.

Levels II and III also use the building codes. In the IBC, fire alarm and detection requirements are in Chapter 9 (Section 907; sprinkler supervision in 903.4), occupancy classification is in Chapter 3, construction types and fire-resistance in Chapters 6 and 7, and means of egress in Chapter 10. In NFPA 101 (Level III), Chapter 9 holds building service and fire protection equipment (9.6 is fire alarm and detection systems), Chapter 7 covers means of egress, and the occupancy chapters (12 and up, in new/existing pairs) hold the occupancy-specific alarm rules. Tab the chapter openers and the index for each book.

Using the index of a printed code

Reading questions like NICET

Logistics

Practice for the real thing. Take the free 20-minute Level I practice exam (no account needed), or get lifetime access to 85-question exams in the NICET format and 552 Level I questions with explanations.

More NICET Fire Alarm study guides